Sequoia Quick Start Guide > Calibrating Sequoia

Next > Multispectral Sensor Button

Before using Sequoia, you must calibrate it. Before starting the calibration, make sure that the two sensors are properly attached and connected to the drone.

The multispectral sensor and the sunshine sensor must be attached perpendicularly. It is recommended to calibrate the two sensors at the same time.

Note: You can calibrate the sensors separately. However the sunshine sensor must be connected to the multispectral sensor to be calibrated.

Make sure that the Sequoia indicator light flashes purple (Diagram D).

Turn the drone on the Z-axis (yaw axis) (Diagram E) until the multispectral sensor indicator light flashes green.

Turn the drone on the Y-axis (pitch axis) (Diagram F) until the multispectral sensor indicator light flashes blue.

Turn the drone on the X-axis (pitch axis) (Diagram G) until the multispectral sensor indicator light changes color.

Note: Once the calibration is complete the color of the multispectral sensor light varies depending on Sequoia's status. For example, if the multispectral sensor memory is full, the indicator light will flash yellow.